Home
News
RDL Platform
Partners
Documentation
Join
About us
Contact us
AC Generator
productAspect
IMF Block
Deprecated
Created 2024-10-25 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block AC Generator in Product aspect.
Identifier:
https://posccaesar.org/imf/blocks/335dc8b1-e5c9-44c9-89b4-e4e448774cde
Types:
Class
IMF Block
NodeShape
Is defined by:
IMF Type Library
Is replaced by:
AC Generator
Attributes
(110)
Attributes
WIDTH
POSITIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
MANUFACTURER
DIRECT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
HEIGHT
ZERO_PHASE_SEQUENCE_RESISTANCE
STATOR_WINDING_LEAKAGE_REACTANCE
SOUND_PRESSURE_LEVEL_MAX
DRIVE_END_BEARING_TYPE
VIBRATION_DETECTOR_TYPE
TYPE
FIELD_CURRENT_RATED_LOAD
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
THRUST_BEARING_TYPE
VIBRATION_DETECTOR_REQUIRED
WINDING_TEMP_SENSOR_COUNT
LUBRICANT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
QUADRAT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
EXCITATION_SYSTEM_TYPE
ALLOWED_AXIAL_THRUST
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
QUADRAT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
LUBE_OIL_TEMP
ROTOR_TYPE
WINDING_TEMPERATURE_DETECTION_REQUIREMENT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
INSULATION_CLASS_ROTOR
LUBE_OIL_PRESSURE
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
TOTAL_WEIGHT
BEARING_TEMP_DETECTORS_TYPE
THRUST_BEARING_COUNT
HEAT_EXCHANGER_MATERIAL
FRAME_SIZE
DRIVE_END_BEARING_COUNT
IP_GRADE
COOLING_METHOD_IC
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
POWER_FACTOR
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
ZERO_PHASE_SEQUENCE_REACTANCE_UNSATURATED
LENGTH
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
DIRECT_AXIS_TRANSIENT_REACTANCE_SATURATED
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
MOMENT_OF_INERTIA
EFFICIENCY_AT_75PCT_LOAD
SPACE_HEATER_REQUIREMENT
DIRECT_AXIS_SHORT_CIRCUIT_TRANSIENT_TIME_CONSTANT
DIRECT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
DC_TIME_CONSTANT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
SUSTAINED_SHORTCIRCUIT_DURATION
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
EARTH_FAULT_CURRENT
NEGATIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
NEGATIVE_PHASE_SEQUENCE_REACTANCE_UNSATURATED
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
DIRECT_AXIS_TRANSIENT_REACTANCE_UNSATURATED
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
DIRECT_AXIS_OPEN_CIRCUIT_TRANSIENT_TIME_CONSTANT
QUADRAT_AXIS_SUBTRANSIENT_REACTANCE
HEAT_EXCHANGER_DRY_WEIGHT
RATED_POWER
NON_DRIVE_END_BEARING_COUNT
DIRECT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
QUADRAT_AXIS_TRANSIENT_REACTANCE
VIBRATION_DETECTORS_COUNT
LEAKAGE_DETECTION_SYSTEM
INSULATION_CLASS_STATOR
FIELD_CURRENT_NO_LOAD
OVERLOAD_CAPABILITY_DURATION
WINDING_TEMP_SENSOR_TYPE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
MAX_ALLOWABLE_TOTAL_HARMONIC_DISTORTION_THD_PCT
BEARING_TEMP_DETECTORS_COUNT
TEMPERATURE_RISE_CLASS_ROTOR
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_SATURATED
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
TEMPERATURE_RISE_CLASS_STATOR
NON_DRIVE_END_BEARING_TYPE
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
SYNCHRONOUS_SPEED
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
EFFICIENCY_AT_100PCT_LOAD
DUTY_TYPE
DESIGN_STANDARD
STATOR_WINDING_DC_RESISTANCE
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
MAX_ALLOWABLE_NEGATIVE_SEQUENCE_CURRENT
COOLANT_WEIGHT
OVERLOAD_CAPABILITY_PCT
EARTHING_SYSTEM
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
SHORT_CIRCUIT_RATIO
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
MOMENT_OF_INERTIA_PRIME_MOVER
NEGATIVE_PHASE_SEQUENCE_REACTANCE_SATURATED
BEARING_LUBRICATION_SYSTEM
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_UNSATURATED
SUSTAINED_SHORTCIRCUIT_PCT
QUADRAT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
PAINTING_SPECIFICATION
ROTOR_WEIGHT
Terminals
(2)
HasTerminal
MechanicalEnergyConnection
AuxConnection
Sub blocks
(2)
HasPart
Terminal Box
Exciter
More info
(1)
Super classes
:
Block