AC Generator
productAspect
IMF Block
Submitted
Created 2025-01-23 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block AC Generator in Product aspect.
Identifier:
https://posccaesar.org/imf/blocks/ac6a74a5-6524-4b72-b2bb-cb1cbd302b1c
Types:
Class
IMF Block
NodeShape
Is defined by:
IMF Type Library
Replaces:
AC Generator
Attributes
(112)
Attributes
OVERLOAD_CAPABILITY_HOURS_DURATION
DIRECT_AXIS_SHORT_CIRCUIT_TRANSIENT_TIME_CONSTANT
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
DC_TIME_CONSTANT
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_UNSATURATED
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
QUADRAT_AXIS_SUBTRANSIENT_REACTANCE
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
FIELD_CURRENT_NO_LOAD
ZERO_PHASE_SEQUENCE_RESISTANCE
ROTOR_WEIGHT
ALLOWED_AXIAL_THRUST
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
SHORT_CIRCUIT_RATIO
EXCITATION_SYSTEM_TYPE
TEMPERATURE_RISE_CLASS_STATOR
INSULATION_CLASS_ROTOR
THRUST_BEARING_TYPE
WINDING_TEMP_SENSOR_TYPE
FRAME_SIZE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
HEAT_EXCHANGER_MATERIAL
MOMENT_OF_INERTIA
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
POWER_FACTOR
SYNCHRONOUS_SPEED
STATOR_WINDING_LEAKAGE_REACTANCE
NON_DRIVE_END_BEARING_COUNT
ZERO_PHASE_SEQUENCE_REACTANCE_UNSATURATED
VIBRATION_DETECTOR_TYPE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
DIRECT_AXIS_TRANSIENT_REACTANCE_SATURATED
BEARING_TEMP_DETECTORS_COUNT
DRIVE_END_BEARING_COUNT
OVERLOAD_CAPABILITY_PCT_FOR_SECONDS_DURATION
QUADRAT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
POSITIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
MANUFACTURER
SOUND_PRESSURE_LEVEL_MAX
DESIGN_STANDARD
WINDING_TEMPERATURE_DETECTION_REQUIRED
SUSTAINED_SHORTCIRCUIT_PCT
DUTY_TYPE
RECOVERY_TIME_VOLTAGE_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
OVERLOAD_CAPABILITY_PCT_FOR_HOURS_DURATION
DIRECT_AXIS_SYNCHRONOUS_REACTANCE_UNSATURATED
INSULATION_CLASS_STATOR
HEIGHT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
VIBRATION_DETECTOR_REQUIRED
DIRECT_AXIS_OPEN_CIRCUIT_TRANSIENT_TIME_CONSTANT
MAX_ALLOWABLE_NEGATIVE_SEQUENCE_CURRENT
NEGATIVE_PHASE_SEQUENCE_REACTANCE_SATURATED
HEAT_EXCHANGER_DRY_WEIGHT
SUSTAINED_SHORTCIRCUIT_DURATION
OVERLOAD_CAPABILITY_SECONDS_DURATION
THRUST_BEARING_COUNT
DIRECT_AXIS_SUBTRANSIENT_REACTANCE_SATURATED
RATED_POWER
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
TYPE
NEGATIVE_PHASE_SEQUENCE_WINDING_RESISTANCE
VIBRATION_DETECTORS_COUNT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
WIDTH
IP_GRADE
ROTOR_TYPE
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
EFFICIENCY_AT_100PCT_LOAD
QUADRAT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
DRIVE_END_BEARING_TYPE
QUADRAT_AXIS_TRANSIENT_REACTANCE
QUADRAT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
LEAKAGE_DETECTION_SYSTEM
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
NEGATIVE_PHASE_SEQUENCE_REACTANCE_UNSATURATED
WINDING_TEMP_SENSOR_COUNT
FIELD_CURRENT_RATED_LOAD
FREQUENCY_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
MOMENT_OF_INERTIA_PRIME_MOVER
LUBE_OIL_PRESSURE
TOTAL_WEIGHT
VOLTAGE_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
LUBRICANT
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_50PCT_TO_0PCT
DIRECT_AXIS_SHORT_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
BEARING_LUBRICATION_SYSTEM
COOLANT_WEIGHT
NON_DRIVE_END_BEARING_TYPE
LUBE_OIL_TEMP
FREQUENCY_DEVIATION_PCT_MAX_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
BEARING_TEMP_DETECTORS_TYPE
EFFICIENCY_AT_75PCT_LOAD
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
LENGTH
RECOVERY_TIME_FREQUENCY_DEVIATION_WHEN_LOAD_CHANGE_100PCT_TO_50PCT
MAX_ALLOWABLE_TOTAL_HARMONIC_DISTORTION_THD_PCT
TEMPERATURE_RISE_CLASS_ROTOR
EARTH_FAULT_CURRENT
DIRECT_AXIS_OPEN_CIRCUIT_SUBTRANSIENT_TIME_CONSTANT
SPACE_HEATER_REQUIRED
EARTHING_SYSTEM
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_50PCT_TO_100PCT
VOLTAGE_DEVIATION_PCT_MIN_WHEN_LOAD_CHANGE_0PCT_TO_50PCT
PAINTING_SPECIFICATION
STATOR_WINDING_DC_RESISTANCE
COOLING_METHOD_IC
DIRECT_AXIS_TRANSIENT_REACTANCE_UNSATURATED
Terminals
(2)
HasTerminal
MechanicalEnergyConnection
MediaFlowConnection
Sub blocks
(2)
HasPart
Terminal Box
Exciter
More info
(1)
Super classes
:
Block