Dry Type Power Transformer
plantAspect
IMF Block
Submitted
Created 2025-01-23 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block Dry Type Power Transformer in Plant aspect.
Identifier:
https://posccaesar.org/imf/blocks/170e055a-7c19-4f06-a325-0620e4e82112
Types:
Class
IMF Block
NodeShape
Is defined by:
IMF Type Library
Replaces:
Dry Type Power Transformer
Attributes
(87)
Attributes
TOLERANCE_PCT_ON_TOTAL_LOSSES
TOLERANCE_PCT_ON_IMPEDANCE_VALUE
LADDER_REQUIREMENT
EXTERNAL_COATING_CHECKING_REQUIRED
IP_GRADE
COUNT
OVERLOADING_REQUIRED
IMPACT_RECORDER_REQUIREMENT_DURING_TRANSPORTATION
ZERO_SEQUENCE_IMPEDANCE_LOWER_LIMIT
FREQUENCY_RESPONSE_ANALYSIS_REQUIRED
MANUFACTURER_MODEL_NO
VIBRATION_LEVEL
CLIMATIC_CLASS
HIGH_TEMPERATURE_INSULATION_REQUIREMENT
BIDIRECTIONAL_ROLLERS_REQUIREMENT
CONFORMITY_ASSESSMENT_SYSTEM_CAS_LEVEL
SUPPLY_VOLTAGE_HARMONIC_CONTENT_PCT
WINDING_TEMPERATURE_RISE
ACCELERATION_ABOVE_1G_DURING_TRANSPORTATION
CURRENT_TRANSFORMER_BURDEN
ALLOWED_SOUND_POWER_LEVEL_MAX
TEMPERATURE_RISE_TEST_REQUIRED
POWER_FACTOR_AT_100PCT_LOAD
VOLTAGE_VARIATION_SIDE
DELTA_CONNECTED_STABILIZING_WINDING_REQUIREMENT
LIFTING_LUGS_REQUIRED
MAX_LIMIT_TRANSPORTATION_WIDTH
PARENT_TAG
MAX_LIMIT_TRANSPORTATION_WEIGHT
SOUND_LEVEL_TEST_REQUIRED
TYPE
RADIATORS_SURFACE_FINISH_TYPE
FANS_AND_LIQUID_PUMP_MOTORS_POWER_CONSUMPTION_TEST_REQUIRED
FUNCTIONAL_CLASS
TRANSFORMER_COOLING_SYSTEM
THERMALLY_UPGRADED_PAPER_REQUIREMENT
FIRE_BEHAVIOR_CLASS
NON_UNIFORM_INSULATION_REQUIREMENT
MARSHALLING_BOX_REQUIREMENT
WINDING_HOT_SPOT_TEMPERATURE_RISE_MEASUREMENTS_REQUIRED
WINDINGS_TO_EARTH_CAPACITANCE_MEASUREMENT_REQUIRED
TAPPING_AT_PRIMARY_SIDE
WINDING_INSULATION_CLASS
SERVICE_DESCRIPTION
TAG_NO
TANK_SURFACE_FINISH_TYPE
TEST_VOLTAGES_ACC_IEC_60076_LIST_2
PAINTING_SPECIFICATION
MAX_LIMIT_TRANSPORTATION_DEPTH
SIMULATED_ON_LOAD_START_TEST_REQUIRED
SUPPLIER
TERTIARY_RATED_VOLTAGE
VOLTAGE_AND_FREQUENCY_RATIO_VARIATION_PCT
TAP_CHANGER_REQUIREMENT
SHORTCIRCUIT_WITHSTAND_TEST_REQUIRED
SHORT_CIRCUIT_CURRENT_PEAK_VALUE
SURFACE_PROTECTION_CORROSIVITY_CATEGORY
SHORT_CIRCUIT_APPARENT_POWER
CORE_EARTHING_TERMINALS_AT_ACCESSIBLE_LOCATION_REQUIREMENT
VECTOR_GROUP
PERCENTAGE_IMPEDANCE_ON_AN_RATING_AT_PRINCIPAL_TAP
OPERATION_SINGLE_PARALLEL
MAX_LIMIT_TRANSPORTATION_HEIGHT
NOLOAD_LOSS_AND_CURRENT_MEASUREMENT_AT_90PCT_AND_110PCT_RATED_VOLTAGE_REQUIRED
ZERO_SEQUENCE_IMPEDANCE_UPPER_LIMIT
PREFORMED_FOR_PORTABLE_EARTHING_APPARATUS
TEST_VOLTAGES_ACC_IEC_60076_LIST_1
WINDING_TO_WINDING_CAPACITANCE_MEASUREMENT_REQUIRED
TRANSIENT_VOLTAGE_TRANSFER_CHARACTERISTICS_DETERMINATION_REQUIRED
STABILIZING_WINDING_EARTHING_TYPE
CURRENT_TRANSFORMER_RATIO
WINDING_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
SHORT_CIRCUIT_IMPEDANCE
DIELECTRIC_TYPE_TESTS_REQUIRED
MANUFACTURER
SHORT_CIRCUIT_CURRENT_RMS_VALUE
SURGE_ARRESTER_REQUIREMENT
VIBRATION_LEVEL_TEST_REQUIREMENT
CURRENT_TRANSFORMER_ACCURACY_CLASS
WINDING_TEMP_SENSOR_TYPE
SURGE_ARRESTER_CLASS
ENVIRONMENTAL_CLASS
PAINT_COLOUR
INSULATING_LIQUID_TEMPERATURE_RISE
DIRECTION_OF_POWER_FLOW
ZERO_SEQUENCE_IMPEDANCE_MEASUREMENT_REQUIRED
BUSDUCT_TYPE
Sub blocks
(4)
HasPart
Cooling Fan
Tap Changer (Incl. OLTC)
Transformer Winding
Termination Point
More info
(1)
Super classes
:
Block