Liquid Immersed Power Transformer
plantAspect
IMF Block
Deprecated
Created 2025-01-23 by
[email protected]
Information
Graph
History
Download
Definition
IMF Type Block Liquid Immersed Power Transformer in Plant aspect.
Identifier:
https://posccaesar.org/imf/blocks/ff44f497-f79e-4a58-90ee-d341542d9cb6
Types:
IMF Block
Class
NodeShape
Is defined by:
IMF Type Library
Replaces:
Liquid Immersed Power Transformer
Is replaced by:
Liquid Immersed Power Transformer
Attributes
(92)
Attributes
TEMPERATURE_RISE_TEST_REQUIRED
MAX_LIMIT_TRANSPORTATION_WIDTH
WINDING_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
PARENT_TAG
SURGE_ARRESTER_REQUIREMENT
WINDING_TEMP_SENSOR_TYPE
REQUIREMENT_OF_FACILITY_FOR_LIQUID_EMISSIONS_FROM_RELIEF_DEVICE_IN_DIRECTION_SPECIFIED
SUPPLY_VOLTAGE_HARMONIC_CONTENT_PCT
WINDING_TEMPERATURE_RISE
FREQUENCY_RESPONSE_ANALYSIS_REQUIRED
WINDINGS_TO_EARTH_CAPACITANCE_MEASUREMENT_REQUIRED
WINDING_INSULATION_CLASS
ROUTINE_TESTS_FOR_EX_O_TYPE_TRANSFORMER_REQUIRED
LADDER_REQUIREMENT
CURRENT_TRANSFORMER_BURDEN
MAX_LIMIT_TRANSPORTATION_DEPTH
DIRECTION_OF_POWER_FLOW
SHORTCIRCUIT_WITHSTAND_TEST_REQUIRED
FIBER_OPTIC_TEMPERATURE_SENSING_REQUIREMENT
DELTA_CONNECTED_STABILIZING_WINDING_REQUIREMENT
MAX_LIMIT_TRANSPORTATION_WEIGHT
WINDING_TO_WINDING_CAPACITANCE_MEASUREMENT_REQUIRED
ACCELERATION_ABOVE_1G_DURING_TRANSPORTATION
TOLERANCE_PCT_ON_TOTAL_LOSSES
NON_UNIFORM_INSULATION_REQUIREMENT
VACUUM_DEFLECTION_TEST_REQUIRED
CURRENT_TRANSFORMER_RATIO
MAGNETIC_LIQUID_LEVEL_GAUGE_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
TRANSIENT_VOLTAGE_TRANSFER_CHARACTERISTICS_DETERMINATION_REQUIRED
SILICA_GEL_BREATHER_TYPE
ONLINE_DISSOLVED_GAS_ANALYSIS_REQUIREMENT
SUDDEN_PRESSURE_RELAY_REQUIREMENT
SIMULATED_ON_LOAD_START_TEST_REQUIRED
ZERO_SEQUENCE_IMPEDANCE_LOWER_LIMIT
TOLERANCE_PCT_ON_IMPEDANCE_VALUE
SUPPLIER
STABILIZING_WINDING_EARTHING_TYPE
SHORT_CIRCUIT_APPARENT_POWER
SILICA_GEL_BREATHER_REQUIREMENT_FOR_MAIN_TANK
ALLOWED_SOUND_POWER_LEVEL_MAX
INSULATING_LIQUID_TEMPERATURE_RISE
PERCENTAGE_IMPEDANCE_ON_AN_RATING_AT_PRINCIPAL_TAP
MARSHALLING_BOX_REQUIREMENT
OPERATIONAL_MODE
BIDIRECTIONAL_ROLLERS_REQUIREMENT
RADIATORS_SURFACE_FINISH_TYPE
ROUTINE_TEST_FOR_EX_P_TYPE_TRANSFORMER_REQUIRED
VOLTAGE_AND_FREQUENCY_RATIO_VARIATION_PCT
WINDING_HOT_SPOT_TEMPERATURE_RISE_MEASUREMENTS_REQUIRED
CURRENT_TRANSFORMER_ACCURACY_CLASS
SERVICE_DESCRIPTION
IMPACT_RECORDER_REQUIREMENT_DURING_TRANSPORTATION
MAX_LIMIT_TRANSPORTATION_HEIGHT
EXTERNAL_COATING_CHECKING_REQUIRED
NOLOAD_LOSS_AND_CURRENT_MEASUREMENT_AT_90PCT_AND_110PCT_RATED_VOLTAGE_REQUIRED
VACUUM_TIGHTNESS_TEST_REQUIRED
BUSDUCT_TYPE
TANK_SURFACE_FINISH_TYPE
PAINTING_SPECIFICATION
FANS_AND_LIQUID_PUMP_MOTORS_POWER_CONSUMPTION_TEST_REQUIRED
BUCHHOLZ_RELAY_WITH_ALARM_AND_TRIP_CONTACT_REQUIREMENT
CONFORMITY_ASSESSMENT_SYSTEM_CAS_LEVEL
VOLTAGE_VARIATION_SIDE
SURGE_ARRESTER_CLASS
COUNT
ZERO_SEQUENCE_IMPEDANCE_MEASUREMENT_REQUIRED
CORE_EARTHING_TERMINALS_AT_ACCESSIBLE_LOCATION_REQUIREMENT
LIQUID_TEMPERATURE_INDICATOR_WITH_ALARM_AND_TRIP_CONTACTS_REQUIREMENT
COVER_TYPE
DISSOLVED_GASSES_MEASUREMENT_IN_DIELECTRIC_LIQUIDS_REQUIRED
LIFTING_LUGS_REQUIREMENT
POWER_FACTOR_AT_100PCT_LOAD
VECTOR_GROUP
SURFACE_PROTECTION_CORROSIVITY_CATEGORY
INSULATING_LIQUID_TYPE
OVERLOADING_REQUIREMENT
HIGH_TEMPERATURE_INSULATION_REQUIREMENT
TAP_CHANGER_REQUIREMENT
PAINT_COLOUR
DIELECTRIC_TYPE_TESTS_REQUIRED
TRANSFORMER_COOLING_SYSTEM
FIBER_OPTIC_TEMPERATURE_SENSOR_CHANNEL_COUNT
MECHANICAL_TEST_REQUIRED
THERMALLY_UPGRADED_PAPER_REQUIREMENT
PRESSURE_RELIEF_DEVICE_REQUIREMENT
SOUND_LEVEL_TEST_REQUIRED
PRESSURE_DEFLECTION_TEST_REQUIRED
CONSERVATOR_DIAPHRAGM_FAILURE_ALARM_CONTACT_REQUIREMENT
LIQUID_LEVEL_INDICATOR_REQUIREMENT
LIQUID_PRESERVATION_SYSTEM_TYPE
TERTIARY_RATED_VOLTAGE
ZERO_SEQUENCE_IMPEDANCE_UPPER_LIMIT
Sub blocks
(5)
HasPart
Tap Changer (Incl. OLTC)
Termination Point
Cooling Fan
Transformer Winding
Transformer Winding
More info
(1)
Super classes
:
Block